VENTEC

VENTEC

APPLICATIONS

Workplace: Data Centres, Utility Rooms, Assembly Rooms, Broadcasting Rooms, Television Studios, Common Rooms, Facilities for Meetings, Conventions and Conferences, Offices, Stage and Studio Rooms
Industry: Power Plants, Production Facilities, Clean Rooms, Laboratories and Research Facilities
Education: Research Rooms, Library Rooms, School, School of Higher Education
Public Institutions: Court Houses, Government Buildings
Recreation and Culture: Banks, Museums, Sales Areas
Public Areas: Entrance Areas
Healthcare: Laboratories

REQUIREMENTS

Design: Elastic, Fabric, Laminate, Perforation, Powder Coating
Hygiene: Antibacterially disinfectable, Cleanable by vacuuming, Virucide disinfectable, Wipeable
Climatic Regulation: Air Permeability, Heating and Cooling, Ventilation
Safety Technology: Electrostatics, Intruder Protection, Radiation Protection
Statics: Heavy-Duty Loads, Seismic Safety, Walkability
Corrosion Protection: Interiors
Fire Protection: Fire Behaviour / Building Material Class
TECHNICAL DATA
For further information please have a look at the data sheet which you will find in the download section.PANELcarrier panel from a welded tubular frame construction with powder coated surfacePANEL THICKNESS30 - 50 mmDIMENSIONAL DEVIATION ACCORDING TO EN 12825class 1SYSTEM WEIGHT40 - 60 kg/m²STANDARD PEDESTAL HEIGHTS25 - 2,000 mmPEDESTAL GRID600 x 600 mmRESISTANCE TO EARTH≥ 1 x 105 ΩSUITABILITY OF COVERINGtextile coveringselastic coveringsloose-laid tilesFIRE PROTECTIONREACTION TO FIRE PERFORMANCE OF THE CARRIER PANEL ACCORDING TO DIN 4102-1A2 (non-combustible)REACTION TO FIRE PERFORMANCE OF THE CARRIER PANEL ACCORDING TO EN 13501-1A1 (non-combustible)CLIMATIC REGULATIONVENTILATIONAir flow at 25 Pa375 - 2,500 m³/h panel (without covering)Free cross-section round hole15 % / 24 % / 38 %Free cross-section slotted hole16 % / 23 %SUSTAINABILITYPRODUCT SELF-DECLARATIONThe self-declaration provides extensive information about all environmental effects of the product. It can be used in the planning or tender phase to assess all sustainability-relevant aspects. It serves as a data basis for building certification systems such as LEED, DGNB, BNB and BREEAM.EPD (ENVIRONMENTAL PRODUCT DECLARATION)A specific EPD for the product can be generated according to the valid standards. (EN 15804/ ISO 14025)CIRCULAR ECONOMYBy implementing the Circular Economy ideology we avoid waste, toxic substances and environmental pollution. The aim is to achieve a technical cycle, which ensures the separation and the complete re-use of all materials.STATICSLOAD AND DEFLECTION CLASSaccording to EN 128252A - 6A (3-15 kN)SAFETY FACTOR2SEISMIC SAFETYInternational Building Code (IBC) Possible in A - F