NORTEC power

NORTEC power

APPLICATIONS

Workplace: Assembly Rooms, Broadcasting Rooms, Television Studios, Common Rooms, Data Centres, Facilities for Meetings, Conventions and Conferences, Stage and Studio Rooms, Utility Rooms, Offices
Recreation and Culture: Banks, Museums, Places of Assembly, Sales Areas, Shopping Centres, Cinemas and Theatres, Concert Halls, Gymnasiums
Education: Library Rooms, Research Rooms, School, School of Higher Education
Industry: Power Plants, Production Facilities, Laboratories and Research Facilities, Clean Rooms
Transport: Airports, Subways and Tunnels, Train Stations
Public Areas: Entrance Areas, Escape Routes
Public Institutions: Court Houses, Government Buildings
Healthcare: Laboratories, Clinics and Hospitals

REQUIREMENTS

Design: Aluminium, Digital Print, Elastic, Fabric, Gypsum, Laminate, Stainless Steel, Steel, Stone, Wood
Hygiene: Antibacterially disinfectable, Cleanable by vacuuming, Virucide disinfectable, Wipeable
Safety Technology: Electrostatics, Intruder Protection, Radiation Protection
Statics: Heavy-Duty Loads, Seismic Safety, Walkability
Fire Protection: Fire Behaviour / Building Material Class, Fire Resistance
Acoustics: Airborne Sound Reduction, Longitudinal Sound Reduction, Impact Sound Reduction
Climatic Regulation: Thermal Insulation
Corrosion Protection: Interiors
Sustainability: Environmental Product Declaration
TECHNICAL DATA
PANELfibre-reinforced calcium sulphate panel, with galvanised steel sheet at bottom side on request, optionally with edge trim protection against damage and humidityPANEL THICKNESS30.5 - 44.5 mmDIMENSIONAL DEVIATION ACCORDING TO EN 12825class 1SYSTEM WEIGHT56 - 81 kg/m²STANDARD PEDESTAL HEIGHTS45 - 2,000 mmPEDESTAL GRID600 x 600 mmRESISTANCE TO EARTH≥ 1 x 106 ΩSUITABILITY OF COVERINGelastic coveringstextile coveringsloose-laid tilesWOODlineSTONElineFor further information please have a look at the data sheet which you will find in the download section.ACOUSTICSNORMALISED FLANKING LEVEL DIFFERENCE DN,F,W49 dB RATED SOUND REDUCTION INDEX RW61 dB REDUCTION OF IMPACT SOUND PRESSURE LEVEL ∆LW 14 dBNORMALISED FLANKING IMPACT SOUND PRESSURE LEVEL LN,F,W70 dBFIRE PROTECTIONREACTION TO FIRE PERFORMANCE OF THE CARRIER PANEL ACCORDING TO DIN 4102-1A2 (non-combustible)REACTION TO FIRE PERFORMANCE OF THE CARRIER PANEL ACCORDING TO EN 13501-1A1 (non-combustible)FIRE RESISTANCE PERFORMANCE OF THE SYSTEM ACCORDING TO DIN 4102-2F30FIRE RESISTANCE PERFORMANCE OF THE SYSTEM ACCORDING TO DIN 13501-2REI 30SUSTAINABILITYSTATICSSEISMIC SAFETYInternational Building Code (IBC)Possible in A - FLOAD AND DEFLECTION CLASSaccording to EN 128256A (6-15 kN)SAFETY FACTOR2