NORTEC

NORTEC

APPLICATIONS

Workplace: Assembly Rooms, Broadcasting Rooms, Television Studios, Common Rooms, Data Centres, Facilities for Meetings, Conventions and Conferences, Offices, Stage and Studio Rooms, Utility Rooms
Recreation and Culture: Banks, Museums, Sales Areas, Shopping Centres, Places of Assembly, Cinemas and Theatres, Stadiums, Concert Halls
Education: Library Rooms, Research Rooms, School, School of Higher Education
Transport: Airports, Subways and Tunnels, Train Stations
Industry: Power Plants, Clean Rooms, Laboratories and Research Facilities, Production Facilities
Public Areas: Entrance Areas, Escape Routes
Public Institutions: Court Houses, Government Buildings
Healthcare: Laboratories, Clinics and Hospitals
Cruise Liner and Ship Fit-out
Residential

REQUIREMENTS

Design: Aluminium, Digital Print, Elastic, Fabric, Glass, Gypsum, Laminate, Stainless Steel, Steel, Stone, Wood
Hygiene: Antibacterially disinfectable, Cleanable by vacuuming, Virucide disinfectable, Wipeable
Safety Technology: Electrostatics, Intruder Protection, Radiation Protection
Acoustics: Airborne Sound Reduction, Longitudinal Sound Reduction, Impact Sound Reduction
Fire Protection: Fire Behaviour / Building Material Class, Fire Resistance
Statics: Seismic Safety, Walkability
Sustainability: Cradle to Cradle®, Environmental Product Declaration
Climatic Regulation: Thermal Insulation
Corrosion Protection: Interiors
TECHNICAL DATA
PANELfibre-reinforced calcium sulphate panel, with galvanised steel sheet at bottom side on request, optionally with surrounding edge trim protection against damage and humidityPANEL THICKNESS16 - 38.5 mmDIMENSIONAL DEVIATION ACCORDING TO EN 12825class 1SYSTEM WEIGHT32 - 62 kg/m²STANDARD PEDESTAL HEIGHTS25 - 2,000 mmPEDESTAL GRID600 x 600 mmRESISTANCE TO EARTH≥ 1 x 106 Ω (depending on covering)SUITABILITY OF COVERINGelastic coveringstextile coveringsloose-laid tilesWOODlineSTONElineFor further information please have a look at the data sheet which you will find in the download section.ACOUSTICSNORMALISED FLANKING LEVEL DIFFERENCE DN,F,W47 - 64 dB*RATED SOUND REDUCTION INDEX RW61 dBREDUCTION OF IMPACT SOUND PRESSURE LEVEL ∆LW11 - 36 dB*NORMALISED FLANKING IMPACT SOUND PRESSURE LEVEL LN,F,W73 - 38 dB**values depending on additional measuresFIRE PROTECTIONREACTION TO FIRE PERFORMANCE OF THE CARRIER PANEL ACCORDING TO DIN 4102-1A2 (non-combustible)REACTION TO FIRE PERFORMANCE OF THE CARRIER PANEL ACCORDING TO EN 13501-1A2 (non-combustible)FIRE RESISTANCE PERFORMANCE OF THE SYSTEM ACCORDING TO DIN 4102-2F30 and F60FIRE RESISTANCE PERFORMANCE OF THE SYSTEM ACCORDING TO EN 13501-2REI30 and REI60SUSTAINABILITYSTATICSSEISMIC SAFETYInternational Building Code (IBC)Possible in A - FLOAD AND DEFLECTION CLASSaccording to EN 128251A (2 kN) - 5A (5 kN)SAFETY FACTOR2