FLOOR and more  power

FLOOR and more power

APPLICATIONS

Recreation and Culture: Banks, Cinemas and Theatres, Concert Halls, Museums, Places of Assembly, Sales Areas, Shopping Centres, Gymnasiums, Stadiums
Workplace: Assembly Rooms, Broadcasting Rooms, Television Studios, Common Rooms, Facilities for Meetings, Conventions and Conferences, Stage and Studio Rooms, Offices
Education: Library Rooms, Research Rooms, School, School of Higher Education
Transport: Airports, Subways and Tunnels, Train Stations
Healthcare: Clinics and Hospitals, Laboratories, Operating Theatres
Industry: Production Facilities, Laboratories and Research Facilities, Power Plants
Public Areas: Entrance Areas, Escape Routes
Public Institutions: Court Houses, Government Buildings
Hotels and Gastronomy: Commercial Kitchens, Restaurants and Canteens, Hotels and Resorts

REQUIREMENTS

Design: Aluminium, Elastic, Fabric, Gypsum, Stainless Steel, Steel, Stone, Wood
Hygiene: Antibacterially disinfectable, Cleanable by vacuuming, Virucide disinfectable, Wipeable
Safety Technology: Electrostatics, Explosion Protection, Intruder Protection, Radiation Protection
Statics: Heavy-Duty Loads, Seismic Safety, Walkability
Climatic Regulation: Heating and Cooling, Thermal Insulation
Corrosion Protection: Interiors, Wet Areas
Fire Protection: Fire Behaviour / Building Material Class, Fire Resistance
Sustainability: Cradle to Cradle®, Environmental Product Declaration
Acoustics: Airborne Sound Reduction, Longitudinal Sound Reduction, Impact Sound Reduction
TECHNICAL DATA
For further information please have a look at the data sheet which you will find in the download section.PANELfibre-reinforced calcium sulphate panel with tongue and grooving, with galvanised steel sheet at bottom side on requestPANEL THICKNESS40 - 44.5 mmDIMENSIONAL DEVIATION ACCORDING TO EN 12825class 1SYSTEM WEIGHTapprox. 62 - 83 kg/m²STANDARD PEDESTAL HEIGHTS210 - 2,000 mmPEDESTAL GRID600 x 600 mmSUITABILITY OF COVERINGtextile coveringselastic coveringsparquet, stone and ceramic coveringsSTONElinedecorative or technical coating systemsFIRE PROTECTIONREACTION TO FIRE PERFORMANCE OF THE CARRIER PANEL ACCORDING TO DIN 4102-1A2 (non-combustible)REACTION TO FIRE PERFORMANCE OF THE CARRIER PANEL ACCORDING TO EN 13501-1A1 (non-combustible)FIRE RESISTANCE PERFORMANCE OF THE SYSTEM ACCORDING TO DIN 4102-2F30FIRE RESISTANCE PERFORMANCE OF THE SYSTEM ACCORDING TO EN 13501-2REI30 and REI60SUSTAINABILITYSTATICSSEISMIC SAFETYInternational Building Code (IBC)Possible in A - FLOAD CLASSaccording to EN 13213 6 (6 - 20 kN) SAFETY FACTOR2