FLOOR and more  comfort

FLOOR and more comfort

APPLICATIONS

Recreation and Culture: Banks, Museums, Shopping Centres, Cinemas and Theatres, Concert Halls, Places of Assembly, Sales Areas
Workplace: Assembly Rooms, Common Rooms, Facilities for Meetings, Conventions and Conferences, Broadcasting Rooms, Television Studios, Stage and Studio Rooms
Education: Library Rooms, School, School of Higher Education, Research Rooms
Transport: Airports, Subways and Tunnels, Train Stations
Public Areas: Entrance Areas, Escape Routes
Public Institutions: Court Houses, Government Buildings
Hotels and Gastronomy: Commercial Kitchens, Hotels and Resorts, Restaurants and Canteens
Healthcare: Clinics and Hospitals, Laboratories
Industry: Laboratories and Research Facilities
Residential

REQUIREMENTS

Design: Aluminium, Elastic, Fabric, Glass, Gypsum, Laminate, Stainless Steel, Steel, Stone, Wood
Hygiene: Antibacterially disinfectable, Cleanable by vacuuming, Virucide disinfectable, Wipeable
Statics: Heavy-Duty Loads, Seismic Safety, Walkability
Corrosion Protection: Interiors, Wet Areas
Fire Protection: Fire Behaviour / Building Material Class, Fire Resistance
Safety Technology: Electrostatics, Intruder Protection
Acoustics: Airborne Sound Reduction, Longitudinal Sound Reduction, Impact Sound Reduction
Climatic Regulation: Heating and Cooling
Sustainability: Environmental Product Declaration
TECHNICAL DATA
PANELfibre-reinforced calcium sulphate panel with tongue and grooving, pre-milled grooves on the top, applied with steel sheet at bottom side on requestPANEL THICKNESS40 - 44,5 mmDIMENSIONAL DEVIATION ACCORDING TO EN 12825class 1SYSTEM WEIGHT52 - 85 kg/m²STANDARD PEDESTAL HEIGHTS40 - 2,000 mmPEDESTAL GRID600 x 600 mmSUITABILITY OF COVERINGtextile coveringselastic coveringsparquetstone and ceramic coveringsFor further information please have a look at the data sheet which you will find in the download section.FIRE PROTECTIONREACTION TO FIRE PERFORMANCE OF THE CARRIER PANEL ACCORDING TO DIN 4102-1A2 (non-combustible)REACTION TO FIRE PERFORMANCE OF THE CARRIER PANEL ACCORDING TO EN 13501-1A1 (non-combustible)FIRE RESISTANCE PERFORMANCE OF THE SYSTEM ACCORDING TO DIN 4102-2F30FIRE RESISTANCE PERFORMANCE OF THE SYSTEM ACCORDING TO EN 13501-2REI30CLIMATIC REGULATIONHEATING PERFORMANCE ACCORDING TO EN 1264-260 - 100 W/m²COOLING PERFORMANCE ACCORDING TO EN 1264-523 - 41 W/m²HEATING LINEØ 17 mmSUSTAINABILITYSTATICSSEISMIC SAFETYInternational Building Code (IBC)Possible in A - FLOAD CLASSaccording to EN 13213 3 (4 kN) - 6 (15 kN) SAFETY FACTOR2