CAVOPEX

CAVOPEX

APPLICATIONS

Workplace: Assembly Rooms, Broadcasting Rooms, Television Studios, Common Rooms, Offices, Facilities for Meetings, Conventions and Conferences, Stage and Studio Rooms
Recreation and Culture: Banks, Museums, Shopping Centres, Places of Assembly
Education: Library Rooms, School, School of Higher Education
Public Areas: Entrance Areas, Escape Routes
Public Institutions: Court Houses, Government Buildings
Healthcare: Clinics and Hospitals, Laboratories, Operating Theatres
Transport: Airports, Subways and Tunnels, Train Stations
Hotels and Gastronomy: Hotels and Resorts, Restaurants and Canteens
Industry: Laboratories and Research Facilities, Production Facilities
Residential

REQUIREMENTS

Design: Aluminium, Elastic, Fabric, Glass, Gypsum, Laminate, Stainless Steel, Steel, Stone, Wood
Hygiene: Antibacterially disinfectable, Cleanable by vacuuming, Virucide disinfectable, Wipeable
Acoustics: Airborne Sound Reduction, Longitudinal Sound Reduction, Impact Sound Reduction
Climatic Regulation: Heating and Cooling, Thermal Insulation
Corrosion Protection: Interiors, Wet Areas
Fire Protection: Fire Behaviour / Building Material Class, Fire Resistance
Safety Technology: Electrostatics, Intruder Protection
Statics: Seismic Safety, Walkability
Sustainability: Environmental Product Declaration
TECHNICAL DATA
PANELfibre-reinforced calcium sulphate panel, optionally with galvanised steel sheet at underside, optionally with edge trim to protect against impact and moisturePANEL THICKNESS28.5 - 38.5 mmDIMENSIONAL DEVIATION ACCORDING TO EN 12825class 1SYSTEM WEIGHT93 kg/m²STANDARD PEDESTAL HEIGHT25 - 2,000 mmPEDESTAL DISTANCE600 x 600 mmELECTROSTATIC CONDUCTIVITY≥ 1 x 106 ΩSUITABILITY OF COVERINGSelastic coveringstextile coveringsloose-laid tilesWOODlineSTONElineACOUSTICSSOUND LEVELSNormalised flanking level difference Dn,f,w48 - 64 dBWeighted sound reduction index Rw61 dBReduction of impact sound pressure level ∆Lw11 - 36 dBNormalised flanking impact sound pressure Ln,f,w73 - 47 dBFIRE PROTECTIONReaction to fire performance of the carrier panel according to DIN 4102-1:A2 (non-combustible)Reaction to fire performance of the carrier panel according to EN 13501-1:A2 (non-combustible)Fire resistance performance of the system according to DIN 4102-1:F30 und F60Fire resistance performance of the system according to EN 13501-1: REI30 und REI60SUSTAINABILITYSTATICSSEISMIC SAFETYInternational Building Code (IBC)available in A - FLOAD AND DEFLECTION CLASSaccording to EN 128251A (2 kN) - 5A (5 kN)SAFETY FACTOR2