AMD-ST 213

AMD-ST 213

APPLICATIONS

Education: Library Rooms,

Hotels and Gastronomy: Hotels and Resorts,

Public Areas: Entrance Areas,

Public Institutions: Court Houses, Government Buildings,

Recreation and Culture: Museums, Places of Assembly, Public Swimming Pools, Sales Areas, Shopping Centres, Stadiums, Banks, Cinemas and Theatres,

Transport: Airports, Train Stations,

Workplace: Assembly Rooms, Common Rooms, Facilities for Meetings, Conventions and Conferences, Offices,

BUILDING PORTFOLIO REQUIREMENTS

Acoustics: Room Acoustics,

Corrosion Protection: Interiors, Wet Areas,

Design: Perforation, Powder Coating, Stainless Steel, Steel,

Fire Protection: Fire Behaviour, Building Material Class,

Sustainability: Environmental Product Declaration,

TECHNICAL DATA
CONSTRUCTION
2 - ceiling panel
6 - L-angle
8/9/114 - vernier suspension
14/15/65 - screw connection
19 - drilling screw
78 - drilling screw
534 - spacer
592 - double hook-on profile

WALL CONNECTION OPTIONS
L-angle
shadow gap trim
open wall connection
CEILING PANELS
Type 3: 

Hook-On, expanded metal turned up
length: 250 - 3,000 mm
width: 200 - 1,250 mm
Type 4: 

Hook-On, expanded metal bordered
length: 250 - 3,000 mm
width: 200 - 1,250 mm
Type 5: 

Hook-On/Swing-Down, expanded metal bordered
length: 250 - 3,000 mm
width: 200 - 1,250 mm
Type 6: 

Hook-On/Swing-Down, expanded metal turned up
length: 250 - 2,000 mm
width: 200 - 1,250 mm
Type 8: 

Hook-On, expanded metal placed on frame
length: 250 - 2,000 mm
width: 200 - 625 mm
Type 9: 

Hook-On/Swing-Down, expanded metal placed on frame
length: 250 - 2,000 mm
width: 200 - 625 mm
For further information please have a look at the data sheet which you will find in the download section.

ACOUSTICS
ROOM ACOUSTICS
up to αw = 1.00, sound absorption class A according to EN ISO 354
up to NRC = 0.90 according to ISO 354, rated to ASTM C 423

FIRE PROTECTION
BUILDING MATERIAL CLASS
A2-s1, d0 according to EN 13501-1
class A (IBC) according to ASTM E 84

CORROSION PROTECTION
exposure class A (interior) according to EN 13964, table 8 and 9

SUSTAINABILITY
SURFACES
POWDER COATINGS
COLOURLINE
MOODLINE

EXPANDED METAL
MESHDESIGN
MESHDESIGN VIVA

ADDITIONAL EQUIPMENT
HEATING AND COOLING FUNCTION
System with integrated heating and cooling technology available: PLAFOTHERM® ST 213.

LUMINAIRES 
Perfectly integrated EFTCG LIGHTING SOLUTIONS are available.

ACOUSTIC INLAYS
Equipped with acoustic inlays like mineral wool, this system contributes significantly to sound protection.

ABSORBER
Equipped with LMD-Absorber on the rear side, expanded metal ceilings are highly sound-absorbent.

BALL-IMPACT RESISTANCE
System with tested ball-impact resistance is available: LMD-ST 213 BWS.

CONTACT
CEILINGS
info@eftcg.com
0216 594 50 30