AMD-E213

AMD-E213

APPLICATIONS

Education: Library Rooms, Research Rooms, School, School of Higher Education,

Healthcare: Clinics and Hospitals, Pharmacies (Production),

Hotels and Gastronomy: Hotels and Resorts,

Industry: Production Facilities,

Pubic Areas: Entrance Areas,

Public Institutions: Court Houses, Government Buildings,

Recreation and Culture: Public Swimming Pools, Banks, Places of Assembly, Stadiums, Cinemas and Theatres, Museums, Sales Areas, Shopping Centres,

Transport: Airports, Train Stations,

Workplace: Facilities for Meetings, Conventions and Conferences, Assembly Rooms, Common Rooms,

BUILDING PORTFOLIO REQUIREMENTS

Acoustics: Room Acoustics,

Corrosion Protection: Interiors, Wet Areas,

Design: Digital Print, Perforation, Powder Coating, Stainless Steel, Steel,

Fire Protection: Fire Behaviour, Building Material Class,

Safety Technology: Explosion Protection,

Statics: Seismic Safety,

Sustainability: Cradle to Cradle®, Environmental Product Declaration,
TECHNICAL DATACONSTRUCTION
1 - ceiling panel6 - L-angle8/9/114 - vernier suspension14/15/65 - screw connection19 - drilling screw78 - drilling screw429 - spacer592 - Hook-On profileWALL CONNECTION OPTIONSL-angleshadow gap trimOpen wall connectionCEILING PANELSType 1:Hook-Onlength: 250 - 3,000 mmwidth: 200 - 1,250 mmType 2:Hook-On, Swing-Down option <1.2 m²length: 250 - 3,000 mmwidth: 200 - 1,250 mmType 3:Hook-On, Swing-Down optionlength: 250 - 3,000 mmwidth: 200 - 1,250 mmFor further information please have a look at the data sheet which you will find in the download section.ACOUSTICSROOM ACOUSTICSup to αw = 1.00, sound absorption class A according to EN ISO 354up to NRC = 0.95 according to ISO 354, rated to ASTM C 423FIRE PROTECTIONBUILDING MATERIAL CLASSA2-s1, d0 according to EN 13501-1class A (IBC) according to ASTM E 84CORROSION PROTECTIONexposure class A (interior) according to EN 13964, table 8 and 9SUSTAINABILITYSURFACESPOWDER COATINGSCOLOURLINEMOODLINEARTLINEGRAPHICLINEPERFORATIONSBASICLINEREGULARLINESPREADLINEDESIGN SURFACESTOUCHDESIGN LUNARSAFETY PROTECTIONEXPLOSION PROTECTIONup to 63 kPa blast pressureSTATICSSEISMIC SAFETYan earthquake-proof construction is possibleADDITIONAL EQUIPMENTVENTILATION COMPONENTSDifferent ventilation components are available:AIRBOX S - SUPPLY AIR ELEMENTSAIRBOX E - EXHAUST AIR ELEMENTSAIRBEAM - HEATED/CHILLED BEAMSHEATING AND COOLING FUNCTIONSystem with integrated heating and cooling technology available: PLAFOTHERM® E 213.LUMINAIRES Perfectly integrated EFTCG LIGHTING SOLUTIONS are available.ACOUSTIC INLAYSEquipped with acoustic inlays like mineral wool, this system contributes significantly to sound protection.BALL-IMPACT RESISTANCESystem with tested ball-impact resistance is available: LMD-E 213 BWS.WIND LOADSSystem with tested wind pressure/suction loads is available: LMD-E 213 WL.
CONTACTCEILINGS Info@eftcg.com0216 594 50 30