AMD-DS 320

AMD-DS 320

APPLICATIONS

Education: Library Rooms, School, School of Higher Education,

Hotels and Gastronomy: Hotels and Resorts,

Public Areas: Entrance Areas,

Public Institutions: Court Houses, Government Buildings,

Recreation and Culture: Museums, Places of Assembly, Stadiums, Banks, Sales Areas, Shopping Centres, Cinemas and Theatres,

Transport: Airports, Train Stations,

Workplace: Assembly Rooms, Broadcasting Rooms, Television Studios, Facilities for Meetings, Conventions and Conferences, Stage and Studio Rooms, Common Rooms, Offices,

BUILDING PORTFOLIO REQUIREMENTS

Acoustics: Room Acoustics,

Corrosion Protection: Interiors,

Design: Digital Print, Perforation, Powder Coating, Steel,

Fire Protection: Fire Behaviour, Building Material Class,

Statics: Seismic Safety, Seismic Safety,

Sustainability: Cradle to Cradle®, Environmental Product Declaration,
TECHNICAL DATA CONSTRUCTION
1 - ceiling panel10/15/65 - threaded rod suspension711 - Hook-On profileCEILING PANELSType 1: 90°-turn-up as individual/border or central panelcanopy length: depending on requirementscanopy width: 200 - 1,250 mmpanel length: 500 - 3,000 mmpanel width: 200 - 1,250 mmType 2: 65°-turn-up as individual panelcanopy length: depending on requirementscanopy width: 200 - 1,250 mmpanel length: 500 - 3,000 mmpanel width: 200 - 1,250 mmType 3: 65°-turn-up as border panel for extension on short sidecanopy length: depending on requirementscanopy width: 200 - 1,250 mmpanel length: 500 - 3,000 mmpanel width: 200 - 1,250 mmType 4: 65°-turn-up as central panel for extension on short sidecanopy length: depending on requirementscanopy width: 200 - 1,250 mmpanel length: 500 - 3,000 mmpanel width: 200 - 1,250 mmFor further information please have a look at the data sheet which you will find in the download section.ACOUSTICSROOM ACOUSTICSequivalent sound absorption area per canopy according to EN ISO 354FIRE PROTECTIONBUILDING MATERIAL CLASSA2-s1, d0 according to EN 13501-1class A (IBC) according to ASTM E 84CORROSION PROTECTIONexposure class A (interior) according to EN 13964, table 8 and 9SUSTAINABILITYSURFACESPOWDER COATINGSCOLOURLINEMOODLINEARTLINEGRAPHICLINEPERFORATIONSBASICLINEREGULARLINESPREADLINESTATICSSEISMIC SAFETYan earthquake-proof construction is possibleADDITIONAL EQUIPMENTVENTILATION COMPONENTSDifferent ventilation components are available:AIRBOX S - SUPPLY AIR ELEMENTSAIRBOX E - EXHAUST AIR ELEMENTSHEATING AND COOLING FUNCTIONSystem with integrated heating and cooling technology available: PLAFOTHERM® DS 320.LUMINAIRES Perfectly integrated EFTCG LIGHTING SOLUTIONS are available.ACOUSTIC INLAYSEquipped with acoustic inlays like mineral wool, this system contributes significantly to sound protection.

CONTACTCEILINGS Info@eftcg.com 0216 594 50 30